Secured by Design Platinum Bi-parting Sliding Gates

Secured by Design Bi-parting Sliding Gates

Secured by Design Bi-parting Sliding Gates
Secured by Design Bi-parting Sliding Gates. Security Rating SR1, SR2, SR3. Secured by Design

***Another World First from Frontier Pitts – Secured by Design Security Rated Biparting Sliding Gates!****

The Secured by Design Platinum Bi-parting Sliding Gates are a set of cantilevered gate which has been successfully withstood forcible attack to Security Rating 1 (A1) for 1 minute, Security Rating 2 (B3) for 3 minutes and Security Rating 3 (C5) for 5 minutes.

The Sliding Cantilevered Gates requires no ground track or support across the roadway. The gateleaf is supported by a main bottom beam, which slides 100mm above the road surface. The balance is provided by a unique runback track, which enables the gate to be fully projected across the roadway without tipping.

The Sliding Gates are 100% duty rated – designed for continuous & frequent use. Power is supplied from a single phase 230V supply.

Sliding Gates Safety control systems: Vehicle detector loops, photocells, ultra-sonic sensors and safety edges are available.

Sliding Gates Accessories: Signage, audible alarms and flashing beacons.

Sliding Gates Access controls: A wide range of access control systems are available.

Please click here to view the choice of Security Rated Gate Infills

Secured by Design SR1 (A1), SR2 (B3) & SR3 (C5) Platinum Sliding Gate Specifications

Features

The Secured by Design Bi-parting pair of SR1 (A1), SR2 (B3) & SR3 (C5) Platinum Sliding Gates

    Basic Specs

  • Automatic Sliding Gate Clear Openings: 6000 – 14000mm
  • Height: 3000mm
  • More details

  • Construction: The sliding gate leaf is a fully welded construction of rectangular hollow section, low carbon steel to BS4848 Pt.2. Standard colour range: Any colour in the RAL colour range
  • Shotblasted, hot zinc sprayed, primed & finished with a final coat of polyurethane paint. Client to advise RAL paint number. This process provides a 20-year corrosion protection system for exterior, industrial polluted inland sites to BS5493, 1977 (Revised 1984). Alternatively, acid dipped then hot galvanized available on smaller gates.
  • Safety: Safety-edges, Vehicle Detector Loops, Safety Photocells, LED Traffic ligh heads, Flashing beacon, Audible alarm
  • Duty Cycle: 100% duty rating
  • Controls: A wide range of access control systems are available.
  • Typical operating speeds of 200-250mm/second, depending on configuration.
  • Accreditations: Secured by Design, BRE Global

Civil Engineering

Sliding Cantilevered Gate leaf Foundation D:500mm and dependent on size of gate
Locator foundation L:800 W:500 D:300
(Note: Power and control wiring ducts to be incorporated into foundations)
Runback = ((Aperture/2) x 1.5) -178mm
For more information please contact the Technical Sales Department on

01293 422800 or email:

[email protected]

Electrical Engineering

Industry standard electricals

Electrical Requirements: 6 amp, 3 wire, 230v, 50hz, single phase supply.

Specifications subject to change and are dependant on product options. Please contact Frontier Pitts to request more information.

 

Product Video

Photo Gallery

Accessories

Signage

Warning and information signs installed on the barrier boom such as ‘STOP’ ‘NO EXIT’ and ‘NO ENTRY’

Pedestrian Warning Sign

Normally placed on the barrier cabinet. Warns pedestrian of the automatic barrier.

Traffic Light System

Traffic Light systems are highly recommended to be installed with all road blocker and bollard systems to advise all users of its position. 100mm traffic light head can be pole or mounted on control cabinet

Vehicle Detector Loops

Vehicle detector loops installed beneath the road surface to detect vehicles. This will prevent the automatic equipment from closing on a vehicle within the aperture. Safety induction loops cut into the road surface. This will prevent the gate from closing on a vehicle within the aperture.

Safety Photocells

Safety Photocells produce beams of light which cross the road way to monitor vehicle and pedestrian movement. If an object breaks this beam, the automatic equipment will stop & reverse. On gate installations, two pairs of photocells are usually fitted. Ultra Sonic Sensors are also available.

Gate Safety Edge

Safety Edges are normally fitted to automatic gates. However they can also be installed beneath a barrier boom. Safety edges prevent the barrier lowering on a person or vehicle in the event it is activated. Safety edges are flexible strips which, if depressed, send a signal to the power source to stop.

Pedestrian Guard Rail

A Pedestrian Guard Rail (fence panels) should be fitted around the runback area of the sliding gate. This is to prevent serious injury to a person should they stray into that area whilst the gate is operating.

Gate Infill

Weldmesh should be clipped to the gates infill bars infill to prevent pedestrians putting their limbs through.
Other infills include palisade pales, sheet and wood infills. For more information please Security Gate Infills page

Sounder

Sounders/Audible Alarms provide an audible warning that the automatic equipment is in operation.

Flashing Beacon

Flashing Beacons provide a visual warning that the automatic equipment is in operation.
Subscribe to get the latest news about our products
We respect your privacy, we will not spam you.